Asbestos & Formaldehyde Analysis:
No Asbestos fiber was found to be present
Formaldehyde measured <5 ug/g beyond limits of instrument
Toxics / Pollutants / Heavy Metals / Carcinogens
None Measured - UNI EN 12457-2
Environmental Exposure Tests:
PASS 100 freeze/thaw cycles - UNI EN 520
Anchor Pull Out Tests:
One 12mm thickness anchor pull out at ~150kg (330 lbs) by panel failure
Two 12mm thickness anchor pull out at ~250Kg (551 lbs) by anchor failure
Fire Rating Classifications per International Standards & Tests
(class A1 is the highest rating for building materials)
European Standards UNI EN ISO 1182 (non-combustible) - Euroclass A1
European Standards UNI EN ISO 1716 (heat resistance) - Euroclass A1
European Standards UNI EN ISO 13501-1 (smoke and flame) - Euroclass A1
European Standards UNI EN ISO (flooring material) - Euroclass A1FL
United States & Canada US ASTM E136 - non-combustible
British Standard 476: Part 4 : 1970 - non-combustible
United States and Canada Surface Burning Characteristics
CAN/ULC-S102 and US ASTM E 84
(Flame Spread Classification "FSC" = 0 / Smoke Developed "SD" = 0)
Flame Spread and Smoke Development Rating is Class 1 or Class A
British Standard 476: Part 7 : 1997, Class 1 for Surface Spread of Flame
ACOUSTICAL ASSEMBLY TEST RESULTS: ASTM E90
9mm (~3/8") Magnesiacore vs ~15mm (5/8") gypsum board
[~15mm gypsum] + [metal stud & batts] + [~15mm gypsum] = STC 43
magnesiacore only wall [9mm] + [metal stud & batts] + [9mm] = STC 48
[9mm / goo / 9mm] + [wood stud & batts] + [~15mm gypsum] = STC 50
[9mm / goo / 9mm] + [wood stud & batts] + [9mm / goo / 9mm] = STC 55
[9mm / goo / 9mm] + [metal stud & batts] + [9mm] = STC 55
[9mm / goo / 9mm] + [metal stud & batts] + [9mm / goo / 9mm] = STC 60
Note * STC 50 is typical code requirement for hotels, motels, apartments,
condominiums, monasteries and convents blocking approx 50 dB (loud speech
cannot be understood). STC 60 is typically specified for highly sensitive areas
blocking around 60 dB off sound volumes (loud speech cannot be heard).
ONE HOUR FIRE RATED ASSEMBLY TEST:
Passed tests for one hour fire rated wall assembly
using 12mm (1/2") Magnesiacore thickness
(After one hour you can see that only the joint compound is breaking down)
NOTE: Separate certification of each fire rated assembly is required in most jurisdictions to comply with local building codes. Fire Rated certification is not currently available for most assemblies and countries. Based on past tests conducted fire rated certification is achievable to higher levels than common fire code / rated materials. Please contact us for more information.
ADHESION TESTING RESULTS
EXCELLENT ADHESION by Direct Application of Acrylic High Build Multi-Colored Elastomeric Decorative Coating
EXCELLENT ADHESION by Direct Application of Flexible Polymer Based Cementitious Base Coat
Upgrade Drywall Comparison Tests:
Gypsum Board vs Magnesiacore Dry Test
Gypsum Board vs Magnesiacore Wet Test